Support for new 3rd- party IP cameras: Arecont AV3105, Bosch VIP X1 and VIP X2
User-defined title image in Report Generator
VSM
Time interval setting between each alert notification, including Camera Motion and Video Lost
Fixed:
Main System
Audio issues with Axis 211M
Pink image problem with Arecont AV3130
Issue of incorrect resolution display with Arecont 5100DN
System errors that occurred when connecting to Sony IP cameras
System errors that occurred when connecting to 16 IP cameras with H.264 codec
Garbled images from IP camera that occurred in the center of 6 x 6 divisions of Quad Enhanced mode
System restart that occurred when the maximum number of PTZ presets were set to between 17 and 64
Failure of "Connection Lost Triggers I/O" function
Failure of GV-Keyboard OSD menu for Spot Monitor that occurred in two card mode
Failure of GV-Keyboard OSD menu for POS Live View when you selected POS related channels between 18 and 32
Failure to restrain users from stopping and starting the recording
Incorrect status of the triggered output after Scene Change related events occurred. The status of the triggered output now is changed to turn on consistently till the event trigger is finished.
Failure to remember the current monitoring status (e.g. start monitoring) upon restart of GV-System through software watchdog
Auto Scan issue in "Digital Matrix" function. Now even though you dont configure auto scan pages, the live mode will be displayed right after popup of a single channel on event trigger.
Issue of saving attributes changes that occurred after the connected IP cameras were powered off
Mismatch issue between POS device and recordings that occurred after the mapped camera was changed
Failure to display POS text overlay that occurred in the raw data images (DSP was disabled) with GV-1120/1240/1480 Cards
Failure to display POS related videos with the Quick Search player launched from Advanced Log Browser. This problem occurred in Camera 2 to Camera 16 when the ID number of POS device and camera matched each other.
System errors that occurred when you selected motion events of Camera 17 to Camera 32 in Advanced Log Browser
Issue of freezing backup status bar in Advanced Log Browser
System restart that occurred after you use "Find Condition" function in Quick Search
Failure to generate the report with Report Generator that occurred when the "24 hours before execution" option was selected and no data were created on the current day
Mismatch issue with Report Generator between DVR name in XML file and location name of DVR
ViewLog
Failure of the "Time Search" function to load all data when one camera had over 1500 or 2000 recorded events
ViewLog restart that occurred in Vista operating system when the selected Multi View mode was in full screen display
Failure of LAN ViewLog
Failure of backup function in Remote ViewLog
Center V2
No notification sent to Center V2 when the IP camera was disconnected from the subscriber
Error message that occurred when the temporary storage space for video attachment was full
Failure to reconnect the subscriber when dispatching the subscriber to the other Center V2 failed
Dispatch Server
Failure to play back the recordings from Center V2 even though the file sharing function was activated
VSM
Incorrect display of "Keep Days" that occurred when the connection between the GV-System client and VSM server was broken and rebuilt
No notification sent to VSM when the IP camera was disconnected from the subscriber
Problem of shutdown and restart during playback at VSM when the associated cameras at GV-System were disabled
Control Center
Failure to access the I/O Central Panel functions by pressing ALT + Tab
Failure to save the self-defined group ordering on the Group List
Failure to access the standard style of Control Center when the VGA card did not support the DirectDraw function
Garbled images in Matrix view when you pressed the Page Down button in the screen division of 8 and with the resolution of 1440 x 960 or 1280 x 800
Icons of channel 1 to channel 16 that failed to flicker on the Remote E-Map
WebCam
Disconnection from WebCam server after megapixel resolution of Arecont 5100 was selected. The problem occurred in the conditions that "Actual Size" was selected and "Frame Title Color" was set to be Black or White on Webcam server
Playback issue when using Object Index Search in Remote Playback (RPB)
Errors to graph the search results of counter events in Event List Query
Message "Install cancel" that occurred during the installation of Multi View through Internet Explorer after the file was renamed or destination directory was changed
Login errors in Multi View caused by creating the same host names
Reconnection issue with all channels in Multi View when one camera disconnected and connected again
Twin DVR Server
Garbled images caused by two Internet Explorer browsers connecting to the same IP camera via WebCam and the resolutions selected for video were different
Mobile Phone Applications
Problem of switching to camera 17 to camera 32 during playback in MSView V2 / V3
Password creation limited to 8 characters in SSView V3
Erroneous text display on BlackBerry Storm 9530 PDA phone
Others
OS errors that occurred when using GV-800 PCI-E and Intel 945G/945P motherboard together in the D1 resolution
Message "Can't find keypro" that occurred when activating Terminal Service in Windows Server 2003 and using GV-600/650/800 V4 Cards
Improved
Auto Scan function allowed for third-party IP cameras
Backup data including Merge List and Backup Log
Improved login dialog box for Single Player
UPnP function for router control not restricted by the version of Microsoft Windows operating system
Changed
Modification of the "Select Brand" dialog box with separate Brand and Device settings
Size limit of Navigation Box in PIP view. Now the size of navigation box can only be diminished to the half of the Insert Window
Removal of server ports no longer used in V8.3, such as TCP Server port 3550
All resolutions of Multi View included in the Software DVD
New driver V2240 for GV-600, 650, 800 V4 and GV804A Cards
New Audio driver V2140 for GV-600, 650, 800 and GV804A Cards